Assessment Year | 2017 |
---|---|
Principal Product | Wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | less than $500 k |
# of Employees | 8 |
Plant Area |
1,000,000
ft2
|
Annual Production | 11,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $261,473 | 3,866,400 |
kWh
|
$0.068 |
Electricity Demand | $57,530 | 8,356 |
kW-mo/yr
|
$6.88 |
TOTAL YEARLY COSTS | $319,003 | |||
RECOMMENDED SAVINGS* | $26,949 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,949 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $10,460 | - |
$9,185
135,081
kWh
|
$1,275
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,475 | $5,000 |
$6,552
96,358
kWh
|
$923
-
kW-mo/yr
|
|
03 | 2.7135: Install occupancy sensors | $2,092 | $1,444 |
$2,092
30,768
kWh
|
- | |
04 | 2.5123: Reduce fluid flow rates | $5,426 | - |
$4,765
70,080
kWh
|
$661
-
kW-mo/yr
|
|
05 | 2.5194: Redesign process | $1,496 | $5,533 |
$8
110
kWh
|
$1,488
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $26,949 | $11,977 |
$22,602
332,397
kWh
|
$4,347
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $26,949 | $11,977 |
$22,602
332,397
kWh
|
$4,347
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs