| Assessment Year | 2014 |
|---|---|
| Principal Product | Automotive Glass |
| NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
| SIC | 3231: Glass Products, Made of Purchased Glass |
| Sales Range | $50 M to 100M |
| # of Employees | 180 |
| Plant Area |
105,316
ft2
|
| Annual Production | 2,687,000
pieces
|
| Production Hrs. Annual | 5,880
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $82,514 | 2,287,680 |
kWh
|
$0.036 |
| Electricity Demand | $57,146 | 4,264 |
kW-mo/yr
|
$13.40 |
| Electricity Fees | $25,218 | - |
|
- |
| Natural Gas | $27,918 | 2,346 |
MMBtu
|
$11.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $65,594 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $5,608 | $2,257 |
$5,608
155,800
kWh
|
- | - | - | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $2,566 | - |
$1,199
33,300
kWh
|
$1,367
-
kW-mo/yr
|
- | - | |
| 03 | 2.7122: Disconnect ballasts | $1,000 | $237 |
$662
18,400
kWh
|
$338
-
kW-mo/yr
|
- | - | |
| 04 | 2.6218: Turn off equipment when not in use | $2,965 | - |
$1,534
42,600
kWh
|
$1,431
-
kW-mo/yr
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,391 | $700 |
$1,944
54,000
kWh
|
$1,447
-
kW-mo/yr
|
- | - | |
| 06 | 2.8114: Change rate schedules or other changes in utility service | $3,232 | - | - | - | $3,232 | - | |
| 07 | 3.6192: Use a less expensive method of waste removal | $20,232 | - | - | - | - | $20,232 | |
| 08 | 3.5316: Contract a wood pallet recycling company | $26,600 | $60,000 | - | - | - | $26,600 | |
| TOTAL RECOMMENDED | $65,594 | $63,194 |
$10,947
304,100
kWh
|
$4,583
-
kW-mo/yr
|
$3,232 | $46,832 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs