| Assessment Year | 1993 |
|---|---|
| Principal Product | Thermocouple Temperature Probes |
| NAICS |
n/a
|
| SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
| Sales Range | $1 M to 5M |
| # of Employees | 45 |
| Plant Area |
12,000
ft2
|
| Annual Production | 41,000
pieces
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $25,966 | 189,332 |
kWh
|
$0.14 |
| Natural Gas | $4,089 | 662 |
MMBtu
|
$6.18 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,758 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,561 | $1,262 |
$2,561
18,757
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $284 | $674 |
$284
2,052
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $53 | $200 |
$53
293
kWh
|
- | |
| 04 | 2.2136: Install / repair insulation on steam lines | $28 | $99 | - |
$28
-
MMBtu
|
|
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,224 | $4,000 |
$1,580
13,482
kWh
|
$(-356.0)
-
MMBtu
|
|
| 06 | 2.7135: Install occupancy sensors | $608 | $400 |
$608
4,396
kWh
|
- | |
| TOTAL RECOMMENDED | $4,758 | $6,635 |
$5,086
38,980
kWh
|
$(-328.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs