| Assessment Year | 2013 |
|---|---|
| Principal Product | wood drying |
| NAICS | 321999: All Other Miscellaneous Wood Product Manufacturing |
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
160,000
ft2
|
| Annual Production | 125
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $145,094 | 3,261,201 |
kWh
|
$0.044 |
| Electricity Demand | $106,149 | 10,424 |
kW-mo/yr
|
$10.18 |
| Electricity Fees | $20,595 | - |
|
- |
| Natural Gas | $160,267 | 49,912 |
MMBtu
|
$3.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $183,711 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $183,711 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,607 | $4,607 |
$2,262
50,832
kWh
|
$2,345
-
kW-mo/yr
|
- | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $2,150 | $1,000 |
$2,150
48,330
kWh
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $145,660 | $993,792 |
$60,560
1,360,900
kWh
|
$85,100
-
kW-mo/yr
|
- | |
| 04 | 2.2135: Repair and eliminate steam leaks | $31,294 | $26,400 | - | - |
$31,294
-
MMBtu
|
|
| TOTAL RECOMMENDED | $183,711 | $1,025,799 |
$64,972
1,460,062
kWh
|
$87,445
-
kW-mo/yr
|
$31,294
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $183,711 | $1,025,799 |
$64,972
1,460,062
kWh
|
$87,445
-
kW-mo/yr
|
$31,294
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs