Assessment Year | 2025 |
---|---|
Principal Product | Custom Metal Parts |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 15 |
Plant Area |
15,000
ft2
|
Annual Production | 44,262
pieces
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $11,580 | 188,760 |
kWh
|
$0.061 |
Electricity Demand | $12,934 | 994 |
kW-mo/yr
|
$13.01 |
Electricity Fees | $4,865 | - |
|
- |
Fuel Oil #4 | $51,951 | 64 |
MMBtu
|
$813.64 |
Other Gas | $18,087 | 1,257 |
MMBtu
|
$14.39 |
Other Energy | $16,606 | 1,041 |
MMBtu
|
$15.95 |
TOTAL YEARLY COSTS | $116,023 | |||
RECOMMENDED SAVINGS* | $363,303 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $45,327 | $12,413 |
$(-557.0)
(-9,128)
kWh
|
$(-548.0)
-
kW-mo/yr
|
- | - | $46,432 | |
02 | 2.9114: Use solar heat to make electricty | $24,006 | $322,608 |
$11,514
188,760
kWh
|
$12,492
-
kW-mo/yr
|
- | - | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $15,192 | $55,000 |
$(-1,320.0)
(-21,638)
kWh
|
$(-94.0)
-
kW-mo/yr
|
- |
$16,606
-
MMBtu
|
- | |
04 | 2.3191: Use demand controller or load shedder | $1,712 | $1,016 |
$806
13,212
kWh
|
$906
-
kW-mo/yr
|
- | - | - | |
05 | 4.114: Add/modify equipment to improve drying process | $165,176 | $50,246 | - | - |
$(-14,970.0)
-
MMBtu
|
- | $180,146 | |
06 | 4.441: Install automatic packing equipment | $89,807 | $7,500 |
$(-56.0)
(-913)
kWh
|
$(-137.0)
-
kW-mo/yr
|
- | - | $90,000 | |
07 | 4.424: Improve space comfort conditioning | $22,083 | $2,620 |
$(-585.0)
(-9,582)
kWh
|
$(-548.0)
-
kW-mo/yr
|
- | - | $23,216 | |
TOTAL RECOMMENDED | $363,303 | $451,403 |
$9,802
160,711
kWh
|
$12,071
-
kW-mo/yr
|
$(-14,970.0)
-
MMBtu
|
$16,606
-
MMBtu
|
$339,794 | ||