Assessment Year | 2024 |
---|---|
Principal Product | Biobased Fertilizers |
NAICS | 325311: Nitrogenous Fertilizer Manufacturing |
SIC | 2873: Nitrogenous Fertilizers |
Sales Range | $1 M to 5M |
# of Employees | 20 |
Plant Area |
50,970
ft2
|
Annual Production | 10,000
ton
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $13,278 | 162,000 |
kWh
|
$0.082 |
Electricity Demand | $4,615 | 1,056 |
kW-mo/yr
|
$4.37 |
Electricity Fees | $2,003 | - |
|
- |
Natural Gas | $14,714 | 1,050 |
MMBtu
|
$14.01 |
LPG | $11,758 | 225 |
MMBtu
|
$52.33 |
Fuel Oil #2 | $63,095 | 2,238 |
MMBtu
|
$28.20 |
TOTAL YEARLY COSTS | $109,463 | |||
RECOMMENDED SAVINGS* | $503,151 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $19,157 | $112,913 |
$13,284
162,000
kWh
|
$5,873
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.3192: Use fossil fuel powered generator during peak demand periods | $1,789 | $872 |
$1,328
16,200
kWh
|
$461
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,409 | $5,855 |
$682
8,319
kWh
|
$727
-
kW-mo/yr
|
- | - | - | - | |
04 | 4.114: Add/modify equipment to improve drying process | $308,175 | $14,388 | - | - |
$8,175
-
MMBtu
|
- | $300,000 | - | |
05 | 4.211: Consider use / purchase of bulk materials where possible | $150,000 | $70,000 | - | - | - | - | - | $150,000 | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $12,621 | $12,380 |
$(-299.0)
(-3,650)
kWh
|
$(-184.0)
-
kW-mo/yr
|
- | $13,104 | - | - | |
07 | 4.424: Improve space comfort conditioning | $10,000 | $1,931 |
$(-299.0)
(-3,650)
kWh
|
$(-184.0)
-
kW-mo/yr
|
- | - | $10,483 | - | |
TOTAL RECOMMENDED | $503,151 | $218,339 |
$14,696
179,219
kWh
|
$6,693
-
kW-mo/yr
|
$8,175
-
MMBtu
|
$13,104 | $310,483 | $150,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs