Assessment Year 2023
Principal Product Magnetic Compressors
NAICS 333999: All Other Miscellaneous General Purpose Machinery Manufacturing
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 119,700
ft2
Annual Production 8,505
units
Production Hrs. Annual 7,665
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $386,785 6,529,724
kWh
Electricity Demand $463,321 31,852
kW-mo/yr
Electricity Fees $276,495 -
Waste Disposal Costs
Water Usage $9,106 3,020
Tgal
Water Disposal $66,195 2,236
Tgal
TOTAL YEARLY COSTS $1,201,902
RECOMMENDED SAVINGS* $241,185 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $156,329

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Primary Raw Material Savings
01 2.9114: Use solar heat to make electricty $91,215 $297,040 $35,358
599,284
kWh
$55,857
-
kW-mo/yr
- -
02 2.3191: Use demand controller or load shedder $84,856 $35,131 $38,525
652,972
kWh
$46,331
-
kW-mo/yr
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $22,121 $756 $22,121
374,937
kWh
- - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $17,751 $17,178 $11,434
193,797
kWh
$6,317
-
kW-mo/yr
- -
05 2.7243: Improve air circulation with destratification fans / other methods $14,162 $12,350 $(-1,605.0)
(-27,200)
kWh
$(-613.0)
-
kW-mo/yr
$16,380 -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,352 - $1,253
21,243
kWh
- $38 $61
07 4.424: Improve space comfort conditioning $9,728 $4,480 $(-4,814.0)
(-81,586)
kWh
$(-1,838.0)
-
kW-mo/yr
$16,380 -
TOTAL RECOMMENDED $241,185 $366,935 $102,272
1,733,447
kWh
$106,054
-
kW-mo/yr
$32,798 $61
TOTAL IMPLEMENTED $156,329 $331,804 $63,747
1,080,475
kWh
$59,723
-
kW-mo/yr
$32,798 $61
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs