Assessment Year 2019
Principal Product Reclaimed Water and Bio-Solids
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $10
M
to 50
M
# of Employees 27
Plant Area 23,959
ft2
Annual Production 3,000,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $389,741 7,077,600
kWh
Electricity Demand $69,096 14,644
kW-mo/yr
Electricity Fees $8,508 -
LPG $42,659 1,039
MMBtu
TOTAL YEARLY COSTS $510,004
RECOMMENDED SAVINGS* $50,990 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $50,990

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.4133: Use most efficient type of electric motors $35,230 $127,650 $25,309
460,169
kWh
$9,921
-
kW-mo/yr
- - -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $5,527 - $4,838
87,971
kWh
- - $350 $339
03 2.7135: Install occupancy sensors $3,486 $3,283 $3,486
63,377
kWh
- - - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $3,073 $2,563 $2,627
47,771
kWh
$446
-
kW-mo/yr
- - -
05 2.2427: Use waste heat from hot flue gases to preheat incoming fluids $2,330 $6,000 - - $2,330
-
MMBtu
- -
06 2.1233: Analyze flue gas for proper air/fuel ratio $1,344 $1,400 - - $1,344
-
MMBtu
- -
TOTAL RECOMMENDED $50,990 $140,896 $36,260
659,288
kWh
$10,367
-
kW-mo/yr
$3,674
-
MMBtu
$350 $339
TOTAL IMPLEMENTED $50,990 $140,896 $36,260
659,288
kWh
$10,367
-
kW-mo/yr
$3,674
-
MMBtu
$350 $339
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs