Assessment Year | 2019 |
---|---|
Principal Product | Food packaging |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 2087: Flavoring Extracts and Flavoring Syrups, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 100 |
Plant Area |
95,000
ft2
|
Annual Production | 40,000
pieces
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $194,564 | 2,067,680 |
kWh
|
$0.094 |
Electricity Demand | $40,036 | 4,214 |
kW-mo/yr
|
$9.50 |
Electricity Fees | $47,658 | - |
|
- |
Natural Gas | $1,182 | 80 |
MMBtu
|
$14.78 |
TOTAL YEARLY COSTS | $283,440 | |||
RECOMMENDED SAVINGS* | $84,688 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $53,586 | $333,760 |
$53,586
570,064
kWh
|
- | - | |
02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $8,685 | $27,820 |
$8,685
92,390
kWh
|
- | - | |
03 | 2.7273: Install desiccant humidity control system | $8,399 | $570 |
$8,399
89,352
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,018 | - |
$725
7,710
kWh
|
$293
-
kW-mo/yr
|
- | |
05 | 2.7243: Improve air circulation with destratification fans / other methods | $13,000 | $18,400 | - | - | $13,000 | |
TOTAL RECOMMENDED | $84,688 | $380,550 |
$71,395
759,516
kWh
|
$293
-
kW-mo/yr
|
$13,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs