| Assessment Year | 2018 |
|---|---|
| Principal Product | Orthopedic Prosthetic and Surgical Appliances and Supplies |
| NAICS | 339113: Surgical Appliance and Supplies Manufacturing |
| SIC | 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies |
| Sales Range | $50 M to 100M |
| # of Employees | 450 |
| Plant Area |
60,000
ft2
|
| Annual Production | 22,000
units
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $221,307 | 2,081,366 |
kWh
|
$0.11 | |
| Electricity Demand | $47,924 | 5,484 |
kW-mo/yr
|
$8.74 | |
| Electricity Fees | $31,209 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $3,753 | 772 |
Tgal
|
$4.86 | |
| Water Disposal | $5,036 | 728 |
Tgal
|
$6.92 | |
| TOTAL YEARLY COSTS | $309,229 | ||||
| RECOMMENDED SAVINGS* | $150,102 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $150,102 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $24,028 | $167,216 |
$24,028
226,678
kWh
|
- | - | - | |
| 02 | 2.7141: Lower light fixtures in high ceiling areas | $9,684 | $1,980 |
$1,032
9,734
kWh
|
$252
-
kW-mo/yr
|
$8,400 | - | |
| 03 | 2.2531: Re-size charging openings or add movable cover or door | $3,844 | $586 |
$3,844
36,263
kWh
|
- | - | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,401 | - |
$2,401
22,650
kWh
|
- | - | - | |
| 05 | 2.7425: Clean or color roof to reduce solar load | $1,145 | $9,600 |
$1,145
10,804
kWh
|
- | - | - | |
| 06 | 4.514: Re-arrange equipment layout to reduce handling costs | $109,000 | $41,200 | - | - | - | $109,000 | |
| TOTAL RECOMMENDED | $150,102 | $220,582 |
$32,450
306,129
kWh
|
$252
-
kW-mo/yr
|
$8,400 | $109,000 | ||
| TOTAL IMPLEMENTED | $150,102 | $220,582 |
$32,450
306,129
kWh
|
$252
-
kW-mo/yr
|
$8,400 | $109,000 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs