| Assessment Year | 2008 |
|---|---|
| Principal Product | Coated Papers |
| NAICS | 322220: Paper Bag and Coated and Treated Paper Manufacturing |
| SIC | 2672: Coated and Laminated Paper, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
78,580
ft2
|
| Annual Production | 11,000
ton
|
| Production Hrs. Annual | 4,368
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $186,351 | 2,357,159 |
kWh
|
$0.079 |
| Electricity Demand | $16,219 | 5,709 |
kW-mo/yr
|
$2.84 |
| Electricity Fees | $69,479 | - |
|
- |
| Other Gas | $10,799 | 0 |
MMBtu
|
$30,854.29 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $89,019 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $34,674 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,980 | $15,208 |
$7,196
99,984
kWh
|
$784
-
kW-mo/yr
|
- | - | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $2,404 | $870 |
$2,404
33,386
kWh
|
- | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $29,339 | $1,246 |
$29,339
371,376
kWh
|
- | - | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $187 | - |
$187
220
kWh
|
- | - | - | |
| 05 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $1,753 | $1,551 |
$1,753
22,195
kWh
|
- | - | - | |
| 06 | 4.111: Add equipment/ operators to reduce production bottleneck | $44,425 | $3,443 | - | - | - | $44,425 | |
| 07 | 3.5217: Reuse / recycle/ sell paper products | $2,931 | - | - | - | $2,931 | - | |
| TOTAL RECOMMENDED | $89,019 | $22,318 |
$40,879
527,161
kWh
|
$784
-
kW-mo/yr
|
$2,931 | $44,425 | ||
| TOTAL IMPLEMENTED | $34,674 | $2,116 |
$31,743
404,762
kWh
|
- | $2,931 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs