Assessment Year 2006
Principal Product Pens, Mousepads
NAICS 339940: Office Supplies (except Paper) Manufacturing
SIC 3951: Pens, Mechanical Pencils, and Parts
Sales Range $50
M
to 100
M
# of Employees 280
Plant Area 146,000
ft2
Annual Production 1
units
Production Hrs. Annual 8,400
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $173,569 7,743,640
kWh
Electricity Demand $57,271 17,057
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $122,332 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $59,231

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
01 2.2511: Insulate bare equipment $7,955 $7,050 $7,955
130,410
kWh
- -
02 2.4235: Remove or close off unneeded compressed air lines $10,965 $5,044 $10,965
158,912
kWh
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,337 $598 $3,337
48,369
kWh
- -
04 2.7141: Lower light fixtures in high ceiling areas $10,260 $2,640 $8,989
147,360
kWh
$1,271
-
kW-mo/yr
-
05 2.7131: Add area lighting switches $4,427 $15,444 $4,427
72,576
kWh
- -
06 2.7292: Lower ceiling to reduce conditioned space $55,146 $7,392 $55,146
799,224
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $26,845 $12,045 $23,596
386,814
kWh
$3,249
-
kW-mo/yr
-
08 3.1291: Eliminate practice of mixing waste streams $3,397 $507 - - $3,397
-
lb
TOTAL RECOMMENDED $122,332 $50,720 $114,415
1,743,665
kWh
$4,520
-
kW-mo/yr
$3,397
-
lb
TOTAL IMPLEMENTED $59,231 $36,278 $51,314
814,031
kWh
$4,520
-
kW-mo/yr
$3,397
-
lb
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs