ITAC Assessment: UF0362
ITAC logo
ITAC Assessment: UF0362
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2005
Principal Product Coffee, tea, gravy, and spices
NAICS 311920: Coffee and Tea Manufacturing
SIC 2095: Roasted Coffee
Sales Range $10
M
to 50
M
# of Employees 46
Plant Area 350,000
ft2
Annual Production 2,300,000
lb
Production Hrs. Annual 2,080
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $169,763 3,437,842
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $51,009 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Solid Waste (haz) Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,108 $706 $11,108
222,153
kWh
-
02 2.7135: Install occupancy sensors $5,310 $2,525 $5,310
106,190
kWh
-
03 2.7221: Lower temperature during the winter season and vice-versa $14,498 - $14,498
289,966
kWh
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $767 - $767
12,024
kWh
-
05 2.4133: Use most efficient type of electric motors $245 $324 $245
4,896
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $8,793 $16,078 $8,793
175,864
kWh
-
07 2.7131: Add area lighting switches $357 $3,655 $357
7,148
kWh
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $288 $245 $288
1,752
kWh
-
09 2.2511: Insulate bare equipment $1,276 $168 $1,276
55,012
kWh
-
10 2.4234: Cool compressor air intake with heat exchanger $8,012 - $8,012
160,244
kWh
-
11 3.5318: Recycle fluorescent lamps $355 $3,496 - $355
-
lb
TOTAL RECOMMENDED $51,009 $27,197 $50,654
1,035,249
kWh
$355
-
lb
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Solid Waste (haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs