Assessment Year | 2004 |
---|---|
Principal Product | Titanium and Zirconium |
NAICS | 331491: Nonferrous Metal (except Copper and Aluminum) Rolling, Drawing, and Extruding |
SIC | 3356: Rolling, Drawing, and Extruding of Nonferrous Metals, Except Copper and Aluminum |
Sales Range | $10 M to 50M |
# of Employees | 102 |
Plant Area |
87,120
ft2
|
Annual Production | 190,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,312,412 | 53,241,209 |
kWh
|
$0.043 |
Natural Gas | $22,084 | 18,669 |
MMBtu
|
$1.18 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $292,078 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,329 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $3,410 | $1,004 |
$2,782
64,696
kWh
|
$628
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,704 | $5,952 |
$7,233
168,199
kWh
|
$471
-
kW-mo/yr
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $22,503 | - |
$22,503
523,330
kWh
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,480 | $3,600 |
$1,480
-
kWh
|
- | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $14,215 | $35,243 |
$13,342
310,285
kWh
|
$873
-
kW-mo/yr
|
- | - | |
06 | 2.1213: Direct warmest air to combustion intake | $16,846 | $85,000 | - | - |
$16,846
-
MMBtu
|
- | |
07 | 3.5242: Recover metals from spent solutions and recycle | $225,920 | $200,000 | - | - | - |
$225,920
-
lb
|
|
TOTAL RECOMMENDED | $292,078 | $330,799 |
$47,340
1,066,510
kWh
|
$1,972
-
kW-mo/yr
|
$16,846
-
MMBtu
|
$225,920
-
lb
|
||
TOTAL IMPLEMENTED | $25,329 | $42,199 |
$23,357
543,180
kWh
|
$1,972
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs