Assessment Year | 2004 |
---|---|
Principal Product | Newspaper |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
Sales Range | $1 M to 5M |
# of Employees | 104 |
Plant Area |
67,500
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 5,840
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $134,474 | 2,071,900 |
kWh
|
$0.065 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,483 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,188 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $11,891 | $44,888 |
$11,891
162,888
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,921 | $4,090 |
$4,921
67,406
kWh
|
- | |
03 | 2.8121: Apply for tax-free status for energy purchases | $11,360 | $65 | - | $11,360 | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $1,907 | $1,200 |
$1,907
26,125
kWh
|
- | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $1,404 | $3,496 | - | $1,404 | |
TOTAL RECOMMENDED | $31,483 | $53,739 |
$18,719
256,419
kWh
|
$12,764 | ||
TOTAL IMPLEMENTED | $18,188 | $5,355 |
$6,828
93,531
kWh
|
$11,360 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs