Assessment Year 2003
Principal Product Aluminum lids
NAICS 331318: Other Aluminum Rolling, Drawing, and Extruding
SIC 3354: Aluminum Extruded Products
Sales Range n/a
# of Employees 275
Plant Area 84,000
ft2
Annual Production 0
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $863,336 18,134,400
kWh
Electricity Demand $119,935 28,309
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $223,241 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $201,862

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings Primary Product Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $14,288 $23,205 $13,043
271,723
kWh
$1,245
-
kW-mo/yr
- -
02 2.7131: Add area lighting switches $2,366 $4,075 $2,366
43,822
kWh
- - -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $12,002 - $12,002
209,803
kWh
- - -
04 2.4133: Use most efficient type of electric motors $26,966 $104,168 $24,055
501,160
kWh
$2,911
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $14,475 $370 $14,475
268,501
kWh
- - -
06 2.8121: Apply for tax-free status for energy purchases $76,790 $65 - - $76,790 -
07 2.7111: Reduce illumination to minimum necessary levels $4,852 $618 $4,618
96,206
kWh
$234
-
kW-mo/yr
- -
08 2.7135: Install occupancy sensors $1,385 $831 $1,385
25,651
kWh
- - -
09 3.6193: Install equipment (eg compactor) to reduce disposal costs $774 $3,496 - - $774 -
10 4.811: Demolish old building to reduce tax and insurance bills $69,343 $420,000 - - - $69,343
TOTAL RECOMMENDED $223,241 $556,828 $71,944
1,416,866
kWh
$4,390
-
kW-mo/yr
$77,564 $69,343
TOTAL IMPLEMENTED $201,862 $547,808 $51,573
1,041,384
kWh
$4,156
-
kW-mo/yr
$76,790 $69,343
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs