| Assessment Year | 2003 |
|---|---|
| Principal Product | Corrugated Cardboard Boxes |
| NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $50 M to 100M |
| # of Employees | 140 |
| Plant Area |
265,000
ft2
|
| Annual Production | 76,762
ton
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $520,396 | 11,059,202 |
kWh
|
$0.047 |
| Electricity Demand | $31,047 | 20,010 |
kW-mo/yr
|
$1.55 |
| Electricity Fees | $36,257 | - |
|
- |
| Natural Gas | $260,248 | 65,734 |
MMBtu
|
$3.96 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $600,700 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $482,075 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $25,707 | $48,985 |
$25,707
450,998
kWh
|
- | - | - | - | - | - | - | |
| 02 | 2.7145: Install skylights | $16,155 | $67,591 |
$14,677
271,789
kWh
|
$2,178
-
kW-mo/yr
|
- | $(-700.0) | - | - | - | - | |
| 03 | 2.2135: Repair and eliminate steam leaks | $1,161 | $225 | - | - |
$1,161
-
MMBtu
|
- | - | - | - | - | |
| 04 | 2.3212: Optimize plant power factor | $3,320 | $3,000 | - | - | - | - | $3,320 | - | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $12,604 | - |
$10,333
181,287
kWh
|
- | - | $326 | - | - | $1,945 | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,426 | $28,971 |
$15,711
290,946
kWh
|
$715
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 07 | 4.445: Install equipment to move product | $70,120 | $150,000 | - | - | - | $70,120 | - | - | - | - | |
| 08 | 4.431: Train operators for maximum operating efficiency | $7,009 | $4,000 | - | - | - | - | - | $7,009 | - | - | |
| 09 | 4.131: Modify process to reduce material use/cost | $448,198 | $37,200 | - | - | - | - | - | - | - | $448,198 | |
| TOTAL RECOMMENDED | $600,700 | $339,972 |
$66,428
1,195,020
kWh
|
$2,893
-
kW-mo/yr
|
$1,161
-
MMBtu
|
$69,746 | $3,320 | $7,009 | $1,945 | $448,198 | ||
| TOTAL IMPLEMENTED | $482,075 | $90,410 |
$25,707
450,998
kWh
|
- |
$1,161
-
MMBtu
|
- | - | $7,009 | - | $448,198 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs