Assessment Year | 2002 |
---|---|
Principal Product | Circuit Assemblies |
NAICS |
n/a
|
SIC | 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere |
Sales Range | $100 M to 500M |
# of Employees | 500 |
Plant Area |
300,000
ft2
|
Annual Production | 30,000
pieces
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $852,126 | 15,993,683 |
kWh
|
$0.053 |
Electricity Demand | $293,885 | 3,008 |
kW-mo/yr
|
$97.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $281,193 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $13,724 | $25,919 | n/a |
$10,362
195,505
kWh
|
$3,362
-
kW-mo/yr
|
- |
02 | 2.7124: Make a practice of turning off lights when not needed | $2,536 | - | n/a |
$2,536
47,840
kWh
|
- | - |
03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $152,665 | $117,000 | n/a |
$152,665
2,091,298
kWh
|
- | - |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,740 | $290 | n/a |
$2,740
37,530
kWh
|
- | - |
05 | 2.7135: Install occupancy sensors | $1,960 | $518 | n/a |
$1,960
26,852
kWh
|
- | - |
06 | 2.7111: Reduce illumination to minimum necessary levels | $106,637 | $10,907 | n/a |
$82,902
1,564,180
kWh
|
$23,735
-
kW-mo/yr
|
- |
07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $931 | $1,895 | n/a | - | - | $931 |
TOTAL RECOMMENDED | $281,193 | $156,529 |
$253,165
3,963,205
kWh
|
$27,097
-
kW-mo/yr
|
$931 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs