| Assessment Year | 2001 |
|---|---|
| Principal Product | |
| NAICS |
n/a
|
| SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
100,000
ft2
|
| Annual Production | 0
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $139,170 | 3,150,400 |
kWh
|
$0.044 |
| Electricity Demand | $77,609 | 9,505 |
kW-mo/yr
|
$8.17 |
| Natural Gas | $572,020 | 52,320 |
MMBtu
|
$10.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $70,137 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $67,182 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,791 | $2,728 |
$6,564
121,554
kWh
|
$1,227
-
kW-mo/yr
|
- | |
| 02 | 2.7135: Install occupancy sensors | $2,566 | $1,457 |
$2,566
47,527
kWh
|
- | - | |
| 03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $5,004 | $6,175 |
$3,127
57,913
kWh
|
$1,877
-
kW-mo/yr
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $869 | $500 |
$917
12,223
kWh
|
- | $(-48.0) | |
| 05 | 2.4133: Use most efficient type of electric motors | $8,758 | $11,274 |
$6,326
117,139
kWh
|
$2,432
-
kW-mo/yr
|
- | |
| 06 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $389 | $1,895 | - | - | $389 | |
| 07 | 4.448: Install automatic part storage / retreval system | $35,100 | $4,494 | - | - | $35,100 | |
| 08 | 4.448: Install automatic part storage / retreval system | $9,660 | $4,612 | - | - | $9,660 | |
| TOTAL RECOMMENDED | $70,137 | $33,135 |
$19,500
356,356
kWh
|
$5,536
-
kW-mo/yr
|
$45,101 | ||
| TOTAL IMPLEMENTED | $67,182 | $29,783 |
$16,934
308,829
kWh
|
$5,536
-
kW-mo/yr
|
$44,712 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs