Assessment Year 2001
Principal Product Precision Ground Gears
NAICS
n/a
SIC 3462: Iron and Steel Forgings
Sales Range $10
M
to 50
M
# of Employees 35
Plant Area 49,000
ft2
Annual Production 35,000
pieces
Production Hrs. Annual 4,675
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $59,630 1,334,640
kWh
Electricity Demand $25,556 3,392
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $93,631 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $22,501

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings Primary Product Savings
01 2.7135: Install occupancy sensors $1,664 $805 $1,664
36,541
kWh
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,182 $410 $1,254
19,589
kWh
- $(-72.0) -
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,194 - $1,194
18,656
kWh
- - -
04 2.7491: Insulate glazing, walls, ceilings, and roofs $16,196 $19,500 $16,196
253,067
kWh
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $8,470 $8,362 $6,423
142,736
kWh
$2,047
-
kW-mo/yr
- -
06 2.7131: Add area lighting switches $648 $232 $648
14,390
kWh
- - -
07 2.7121: Utilize daylight whenever possible in lieu of artificial light $5,353 $15,176 $3,063
68,063
kWh
$2,485
-
kW-mo/yr
$(-195.0) -
08 2.7232: Replace existing hvac unit with high efficiency model $12,201 $30,000 $9,481
210,700
kWh
$2,720
-
kW-mo/yr
- -
09 3.7193: Use high pressure wash systems $41,558 $175,800 - - - $41,558
10 2.7142: Utilize higher efficiency lamps and/or ballasts $5,165 $5,237 $1,220
(-27,115)
kWh
$(-524.0)
-
kW-mo/yr
- $4,469
TOTAL RECOMMENDED $93,631 $255,522 $41,143
736,627
kWh
$6,728
-
kW-mo/yr
$(-267.0) $46,027
TOTAL IMPLEMENTED $22,501 $39,004 $17,806
387,415
kWh
$4,767
-
kW-mo/yr
$(-72.0) -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs