| Assessment Year | 2001 |
|---|---|
| Principal Product | Roofing Products |
| NAICS |
n/a
|
| SIC | 2231: Broadwoven Fabric Mills, Wool (Including Dyeing and Finishing) |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
300,000
ft2
|
| Annual Production | 69,484
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $177,052 | 2,569,451 |
kWh
|
$0.069 |
| Electricity Demand | $48,636 | 5,528 |
kW-mo/yr
|
$8.80 |
| Fuel Oil #2 | $301,704 | 274,276 |
MMBtu
|
$1.10 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $100,310 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,449 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,548 | $9,647 |
$4,358
56,599
kWh
|
$1,190
-
kW-mo/yr
|
- | - | |
| 02 | 2.8121: Apply for tax-free status for energy purchases | $17,357 | $50 | - | - | - | $17,357 | |
| 03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $20,280 | $49,350 |
$14,646
190,208
kWh
|
$6,124
-
kW-mo/yr
|
- | $(-490.0) | |
| 04 | 2.4238: Do not use compressed air for personal cooling | $6,860 | $1,212 |
$6,860
71,454
kWh
|
- | - | - | |
| 05 | 2.4133: Use most efficient type of electric motors | $6,066 | $450 |
$5,266
69,406
kWh
|
$800
-
kW-mo/yr
|
- | - | |
| 06 | 3.4155: Meter waste water | $5,235 | $1,500 | - | - |
$5,235
-
Tgal
|
- | |
| 07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $645 | $1,895 | - | - | - | $645 | |
| 08 | 3.5316: Contract a wood pallet recycling company | $1,485 | - | - | - | - | $1,485 | |
| 09 | 4.448: Install automatic part storage / retreval system | $29,484 | $5,113 | - | - | - | $29,484 | |
| 10 | 4.431: Train operators for maximum operating efficiency | $7,350 | $800 | - | - | - | $7,350 | |
| TOTAL RECOMMENDED | $100,310 | $70,017 |
$31,130
387,667
kWh
|
$8,114
-
kW-mo/yr
|
$5,235
-
Tgal
|
$55,831 | ||
| TOTAL IMPLEMENTED | $20,449 | $10,897 |
$9,624
126,005
kWh
|
$1,990
-
kW-mo/yr
|
- | $8,835 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs