| Assessment Year | 2001 |
|---|---|
| Principal Product | Medical Filtering and Separating Membranes |
| NAICS |
n/a
|
| SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
600,000
ft2
|
| Annual Production | 9,200,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $194,847 | 7,658,400 |
kWh
|
$0.025 |
| Electricity Demand | $139,245 | 16,248 |
kW-mo/yr
|
$8.57 |
| Natural Gas | $295,240 | 34,089 |
MMBtu
|
$8.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $49,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $24,711 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $9,057 | $10,208 |
$5,560
222,382
kWh
|
$3,497
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $696 | $660 |
$413
16,500
kWh
|
$283
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $20,871 | $62,226 |
$20,871
474,351
kWh
|
- | - | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,241 | $1,520 |
$569
22,776
kWh
|
$267
-
kW-mo/yr
|
$380 | $1,025 | - | |
| 05 | 2.7124: Make a practice of turning off lights when not needed | $2,260 | - |
$1,341
53,640
kWh
|
$919
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.7145: Install skylights | $2,897 | $3,188 |
$1,035
41,399
kWh
|
$1,892
-
kW-mo/yr
|
$(-30.0) | - | - | |
| 07 | 2.7135: Install occupancy sensors | $2,853 | $767 |
$2,853
64,848
kWh
|
- | - | - | - | |
| 08 | 3.5316: Contract a wood pallet recycling company | $1,800 | - | - | - | $1,800 | - | - | |
| 09 | 4.448: Install automatic part storage / retreval system | $6,500 | $4,612 | - | - | - | - | $6,500 | |
| TOTAL RECOMMENDED | $49,175 | $83,181 |
$32,642
895,896
kWh
|
$6,858
-
kW-mo/yr
|
$2,150 | $1,025 | $6,500 | ||
| TOTAL IMPLEMENTED | $24,711 | $17,107 |
$10,323
363,646
kWh
|
$4,683
-
kW-mo/yr
|
$2,180 | $1,025 | $6,500 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs