Assessment Year | 2001 |
---|---|
Principal Product | Treated Metal Parts |
NAICS |
n/a
|
SIC | 3398: Metal Heat Treating |
Sales Range | $1 M to 5M |
# of Employees | 70 |
Plant Area |
11,450
ft2
|
Annual Production | 20,075
units
|
Production Hrs. Annual | 6,708
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $52,237 | 1,252,000 |
kWh
|
$0.042 |
Electricity Demand | $37,132 | 5,122 |
kW-mo/yr
|
$7.25 |
Natural Gas | $23,401 | 9,450 |
MMBtu
|
$2.48 |
Other Energy | $27,240 | 1,141 |
MMBtu
|
$23.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,043 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,014 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $9,184 | $50 | - | - | - | $9,184 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,027 | $2,302 |
$833
17,711
kWh
|
$194
-
kW-mo/yr
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,439 | - |
$1,439
25,698
kWh
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,553 | $220 |
$2,553
31,767
kWh
|
- | - | - | |
05 | 2.2511: Insulate bare equipment | $8,200 | $6,910 | - | - |
$8,200
-
MMBtu
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $4,725 | $14,788 |
$4,725
76,496
kWh
|
- | - | - | |
07 | 2.7145: Install skylights | $1,180 | $5,321 |
$1,180
15,424
kWh
|
- | - | - | |
08 | 2.4235: Remove or close off unneeded compressed air lines | $5,285 | $75 |
$5,285
65,253
kWh
|
- | - | - | |
09 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $1,210 | $7,000 | - | - | - | $1,210 | |
10 | 3.7141: Improve cleaning efficiency by maintaining cleaning system | $282 | $260 |
$257
5,487
kWh
|
$25
-
kW-mo/yr
|
- | - | |
11 | 2.2424: Use heat in flue gases to preheat products or materials | $2,958 | $6,000 |
$869
18,469
kWh
|
$2,089
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $38,043 | $42,926 |
$17,141
256,305
kWh
|
$2,308
-
kW-mo/yr
|
$8,200
-
MMBtu
|
$10,394 | ||
TOTAL IMPLEMENTED | $26,014 | $23,695 |
$14,522
215,183
kWh
|
$2,308
-
kW-mo/yr
|
- | $9,184 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs