Assessment Year | 2000 |
---|---|
Principal Product | Newspaper Publishing and Offset Printing |
NAICS |
n/a
|
SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
Sales Range | n/a |
# of Employees | 1,950 |
Plant Area |
826,000
ft2
|
Annual Production | 133,952,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,060,017 | 30,941,384 |
kWh
|
$0.034 |
Electricity Demand | $614,120 | 59,483 |
kW-mo/yr
|
$10.32 |
Natural Gas | $27,491 | 4,823 |
MMBtu
|
$5.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $462,371 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $70,761 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,359 | $14,443 |
$4,836
142,145
kWh
|
$1,523
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,169 | $1,075 |
$3,169
93,200
kWh
|
- | - | - | - | - | |
03 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $391,026 | $1,500,000 |
$845,257
24,859,907
kWh
|
$461,676
-
kW-mo/yr
|
$(-730,147.0)
-
MMBtu
|
- | $(-185,760.0) | - | |
04 | 2.2221: Use immersion heating in tanks, melting pots, etc | $584 | $20 | - | - | - |
$584
-
MMBtu
|
- | - | |
05 | 2.8121: Apply for tax-free status for energy purchases | $49,313 | $50 | - | - | - | - | - | $49,313 | |
06 | 4.652: Replace existing equipment with more suitable substitutes | $1,959 | $3,000 |
$589
17,292
kWh
|
$245
-
kW-mo/yr
|
- | - | $1,125 | - | |
07 | 4.111: Add equipment/ operators to reduce production bottleneck | $9,961 | $6,400 |
$(-74.0)
(-2,052)
kWh
|
$(-185.0)
-
kW-mo/yr
|
- | - | $10,220 | - | |
TOTAL RECOMMENDED | $462,371 | $1,524,988 |
$853,777
25,110,492
kWh
|
$463,259
-
kW-mo/yr
|
$(-730,147.0)
-
MMBtu
|
$584
-
MMBtu
|
$(-174,415.0) | $49,313 | ||
TOTAL IMPLEMENTED | $70,761 | $24,968 |
$8,520
250,585
kWh
|
$1,583
-
kW-mo/yr
|
- | - | $11,345 | $49,313 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs