Assessment Year | 2000 |
---|---|
Principal Product | Fiberglass boats |
NAICS |
n/a
|
SIC | 3732: Boat Building and Repairing |
Sales Range | $10 M to 50M |
# of Employees | 165 |
Plant Area |
80,000
ft2
|
Annual Production | 520
pieces
|
Production Hrs. Annual | 4,208
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,665 | 2,114,889 |
kWh
|
$0.021 |
Electricity Demand | $17,009 | 2,130 |
kW-mo/yr
|
$7.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $301,118 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $3,623 | $50 | n/a | - | - | $3,623 |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $203 | $360 | n/a |
$100
4,982
kWh
|
$16
-
kW-mo/yr
|
$87 |
03 | 2.6218: Turn off equipment when not in use | $4,849 | - | n/a |
$3,284
160,023
kWh
|
$1,565
-
kW-mo/yr
|
- |
04 | 2.7124: Make a practice of turning off lights when not needed | $532 | - | n/a |
$460
22,274
kWh
|
$72
-
kW-mo/yr
|
- |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,345 | $221 | n/a |
$1,345
47,479
kWh
|
- | - |
06 | 3.4155: Meter waste water | $2,499 | $2,000 | n/a | - | - | $2,499 |
07 | 3.5316: Contract a wood pallet recycling company | $470 | - | n/a | - | - | $470 |
08 | 4.111: Add equipment/ operators to reduce production bottleneck | $265,485 | - | n/a | - | - | $265,485 |
09 | 4.431: Train operators for maximum operating efficiency | $2,080 | $420 | n/a | - | - | $2,080 |
10 | 4.423: Move product using mechanical means | $18,992 | $10,000 | n/a | - | - | $18,992 |
11 | 4.821: Pay bills on time to avoid late fees | $1,040 | - | n/a | - | - | $1,040 |
TOTAL RECOMMENDED | $301,118 | $13,051 |
$5,189
234,758
kWh
|
$1,653
-
kW-mo/yr
|
$294,276 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs