Assessment Year | 2000 |
---|---|
Principal Product | Automotive Parts |
NAICS |
n/a
|
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $50 M to 100M |
# of Employees | 490 |
Plant Area |
280,000
ft2
|
Annual Production | 1,645,000
units
|
Production Hrs. Annual | 5,640
hrs
|
Location (State) | Florida |
View Case Study |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $520,047 | 12,384,232 |
kWh
|
$0.042 |
Electricity Demand | $30,944 | 25,268 |
kW-mo/yr
|
$1.22 |
Natural Gas | $51,838 | 21,674 |
MMBtu
|
$2.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $201,332 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $80,658 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,938 | - |
$1,788
45,721
kWh
|
$150
-
kW-mo/yr
|
- | - | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,096 | - |
$857
20,516
kWh
|
$239
-
kW-mo/yr
|
- | - | |
03 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $25,982 | - | - | - |
$25,982
-
lb
|
- | |
04 | 3.5316: Contract a wood pallet recycling company | $53,580 | - | - | - |
$53,580
-
lb
|
- | |
05 | 4.521: Clear and rent existing space | $118,736 | - | - | - | - | $118,736 | |
TOTAL RECOMMENDED | $201,332 | - |
$2,645
66,237
kWh
|
$389
-
kW-mo/yr
|
$79,562
-
lb
|
$118,736 | ||
TOTAL IMPLEMENTED | $80,658 | - |
$857
20,516
kWh
|
$239
-
kW-mo/yr
|
$79,562
-
lb
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs