| Assessment Year | 2000 |
|---|---|
| Principal Product | Automotive Parts |
| NAICS |
n/a
|
| SIC | 3231: Glass Products, Made of Purchased Glass |
| Sales Range | $50 M to 100M |
| # of Employees | 490 |
| Plant Area |
280,000
ft2
|
| Annual Production | 1,645,000
units
|
| Production Hrs. Annual | 5,640
hrs
|
| Location (State) | Florida |
| View Case Study | |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $520,047 | 12,384,232 |
kWh
|
$0.042 |
| Electricity Demand | $30,944 | 25,268 |
kW-mo/yr
|
$1.22 |
| Natural Gas | $51,838 | 21,674 |
MMBtu
|
$2.39 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $201,332 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $80,658 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,938 | - |
$1,788
45,721
kWh
|
$150
-
kW-mo/yr
|
- | - | |
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,096 | - |
$857
20,516
kWh
|
$239
-
kW-mo/yr
|
- | - | |
| 03 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $25,982 | - | - | - |
$25,982
-
lb
|
- | |
| 04 | 3.5316: Contract a wood pallet recycling company | $53,580 | - | - | - |
$53,580
-
lb
|
- | |
| 05 | 4.521: Clear and rent existing space | $118,736 | - | - | - | - | $118,736 | |
| TOTAL RECOMMENDED | $201,332 | - |
$2,645
66,237
kWh
|
$389
-
kW-mo/yr
|
$79,562
-
lb
|
$118,736 | ||
| TOTAL IMPLEMENTED | $80,658 | - |
$857
20,516
kWh
|
$239
-
kW-mo/yr
|
$79,562
-
lb
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs