Assessment Year | 2000 |
---|---|
Principal Product | Sulfuric Acid |
NAICS |
n/a
|
SIC | 2874: Phosphatic Fertilizers |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
52,000
ft2
|
Annual Production | 930,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $552,050 | 13,801,290 |
kWh
|
$0.040 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,797,128 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Primary Product Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,848 | $2,526 |
$1,848
46,307
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $20,280 | $81,187 |
$20,280
466,295
kWh
|
- | |
03 | 2.5194: Redesign process | $418,000 | $141,700 |
$418,000
10,451,641
kWh
|
- | |
04 | 4.212: Adopt in-house material generation | $1,357,000 | $6,200,000 |
$(-713,000.0)
(-17,844,080)
kWh
|
$2,070,000 | |
TOTAL RECOMMENDED | $1,797,128 | $6,425,413 |
$(-272,872.0)
(-6,879,837)
kWh
|
$2,070,000 | ||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs