| Assessment Year | 1999 |
|---|---|
| Principal Product | Sulfuric Acid |
| NAICS |
n/a
|
| SIC | 2874: Phosphatic Fertilizers |
| Sales Range | $10 M to 50M |
| # of Employees | 33 |
| Plant Area |
58,600
ft2
|
| Annual Production | 949,000
ton
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $470,288 | 11,757,327 |
kWh
|
$0.040 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,407,565 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Primary Product Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $17,565 | $69,897 |
$17,565
439,332
kWh
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $3,200,000 | $17,000,000 |
$3,200,000
80,592,029
kWh
|
- | |
| 03 | 4.212: Adopt in-house material generation | $2,190,000 | $8,100,000 |
$(-910,000.0)
(-22,776,085)
kWh
|
$3,100,000 | |
| TOTAL RECOMMENDED | $5,407,565 | $25,169,897 |
$2,307,565
58,255,276
kWh
|
$3,100,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs