Assessment Year 1998
Principal Product Lumber
NAICS
n/a
SIC 2421: Sawmills and Planing Mills, General
Sales Range $5
M
to 10
M
# of Employees 45
Plant Area 60,000
ft2
Annual Production 10,000
bushels
Production Hrs. Annual 2,025
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $55,891 1,216,002
kWh
Electricity Demand $53,913 8,208
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $48,030 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,394

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,649 $597 $1,062
18,464
kWh
$587
-
kW-mo/yr
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $537 $680 $537
5,569
kWh
- - -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,589 $1,609 $1,589
34,291
kWh
- - -
04 2.4133: Use most efficient type of electric motors $8,515 $4,900 $6,062
128,957
kWh
$2,453
-
kW-mo/yr
- -
05 3.5248: Separate and recycle scrap metal to foundry or for sale $1,800 - - - - $1,800
06 4.812: Apply for investment incentives $6,857 $50 - - $6,857 -
07 4.322: Eliminate old stock and modify inventory control $27,083 - - - $27,083 -
TOTAL RECOMMENDED $48,030 $7,836 $9,250
187,281
kWh
$3,040
-
kW-mo/yr
$33,940 $1,800
TOTAL IMPLEMENTED $7,394 $730 $537
5,569
kWh
- $6,857 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings