Assessment Year 1998
Principal Product telephone directories
NAICS
n/a
SIC 2752: Commercial Printing, Lithographic
Sales Range $10
M
to 50
M
# of Employees 180
Plant Area 250,000
ft2
Annual Production 25,000,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $612,261 11,230,657
kWh
Electricity Demand $96,997 22,380
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $215,226 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,360

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $5,120 $2,936 $4,654
84,701
kWh
$466
-
kW-mo/yr
- -
02 2.7134: Use photocell controls $710 $400 $710
12,896
kWh
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $9,950 $25,614 $9,055
164,713
kWh
$895
-
kW-mo/yr
- -
04 2.7232: Replace existing hvac unit with high efficiency model $2,353 $22,215 $1,903
34,584
kWh
$450
-
kW-mo/yr
- -
05 2.7447: Install vinyl strip / high speed / air curtain doors $7,360 $5,200 $7,360
133,939
kWh
- - -
06 2.7232: Replace existing hvac unit with high efficiency model $40,304 $131,764 $40,304
732,708
kWh
- - -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,375 $2,000 $10,375
164,713
kWh
- - -
08 2.4133: Use most efficient type of electric motors $453 $4,407 $376
6,741
kWh
$77
-
kW-mo/yr
- -
09 3.5316: Contract a wood pallet recycling company $15,000 - - - $15,000
-
lb
-
10 3.8132: Use less toxic and volatile solvent substitutes $3,415 $500 - - - $3,415
11 3.5311: Recover and reuse waste material $97,917 - - - $18,750
-
lb
$79,167
12 2.8121: Apply for tax-free status for energy purchases $21,649 - - - - $21,649
13 2.7142: Utilize higher efficiency lamps and/or ballasts $620 $780 $326
5,862
kWh
- - $294
TOTAL RECOMMENDED $215,226 $195,816 $75,063
1,340,857
kWh
$1,888
-
kW-mo/yr
$33,750
-
lb
$104,525
TOTAL IMPLEMENTED $7,360 $5,200 $7,360
133,939
kWh
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs