Assessment Year | 1997 |
---|---|
Principal Product | Steel Wire Mesh |
NAICS |
n/a
|
SIC | 3496: Miscellaneous Fabricated Wire Products |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
200,000
ft2
|
Annual Production | 60,000
ton
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $222,494 | 5,738,570 |
kWh
|
$0.039 |
Electricity Demand | $133,729 | 14,899 |
kW-mo/yr
|
$8.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $111,404 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,468 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,839 | $1,956 |
$2,031
53,341
kWh
|
$808
-
kW-mo/yr
|
- | - | - | |
02 | 2.7134: Use photocell controls | $1,078 | $1,100 |
$1,078
28,429
kWh
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,073 | $1,913 |
$634
16,706
kWh
|
$439
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,556 | $1,850 |
$5,556
146,249
kWh
|
- | - | - | - | |
05 | 2.4226: Use / purchase optimum sized compressor | $1,573 | - | - |
$1,573
-
kW-mo/yr
|
- | - | - | |
06 | 2.3212: Optimize plant power factor | $9,095 | $36,500 | - | - | - | $9,095 | - | |
07 | 2.8121: Apply for tax-free status for energy purchases | $58,776 | - | - | - |
$7,347
-
lb
|
- | $51,429 | |
08 | 3.7121: Improve handling practices | $12,852 | $6,000 | - | - | - | $12,852 | - | |
09 | 4.321: Optimize production lot sizes and inventories | $18,562 | $8,530 | - | - | - | $18,562 | - | |
TOTAL RECOMMENDED | $111,404 | $57,849 |
$9,299
244,725
kWh
|
$2,820
-
kW-mo/yr
|
$7,347
-
lb
|
$40,509 | $51,429 | ||
TOTAL IMPLEMENTED | $9,468 | $5,719 |
$8,221
216,296
kWh
|
$1,247
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs