Assessment Year | 1997 |
---|---|
Principal Product | Automatic Inflators |
NAICS |
n/a
|
SIC | 3841: Surgical and Medical Instruments and Apparatus |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
55,000
ft2
|
Annual Production | 25,000
pieces
|
Production Hrs. Annual | 2,385
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $72,103 | 1,079,132 |
kWh
|
$0.067 |
Electricity Demand | $16,967 | 3,548 |
kW-mo/yr
|
$4.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $47,194 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $1,524 | $352 |
$1,226
21,395
kWh
|
$298
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,163 | $34,581 |
$8,999
157,972
kWh
|
$2,164
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $570 | $820 |
$570
9,965
kWh
|
- | - | - | |
04 | 2.7272: Install heat pipes / raise cooling setpoint | $2,876 | $3,700 |
$2,052
36,049
kWh
|
$824
-
kW-mo/yr
|
- | - | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,421 | $8,860 | - | - | $3,421 | - | |
06 | 3.1175: Use a different or recycled raw material | $24,578 | - | - | - | - | $24,578 | |
07 | 2.8121: Apply for tax-free status for energy purchases | $3,062 | - | - | - | $3,062 | - | |
TOTAL RECOMMENDED | $47,194 | $48,313 |
$12,847
225,381
kWh
|
$3,286
-
kW-mo/yr
|
$6,483 | $24,578 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs