| Assessment Year | 1997 | 
|---|---|
| Principal Product | Wood Doors | 
| NAICS | n/a | 
| SIC | 2431: Millwork | 
| Sales Range | $10 Mto 50 M | 
| # of Employees | 130 | 
| Plant Area | 125,000 
ft2
 | 
| Annual Production | 550,000 
pieces
 | 
| Production Hrs. Annual | 5,460 
hrs
 | 
| Location (State) | Florida | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $103,113 | 1,656,800 | 
kWh
 | $0.062 | 
| Electricity Demand | $25,138 | 4,449 | 
kW-mo/yr
 | $5.65 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $55,254 | See individual recommendations below*Non-energy impacts included in savings. | ||
| IMPLEMENTED SAVINGS* | $16,442 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | 
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,763 | $23,909 | $5,621 90,563
                                 
kWh
 | $1,142 -
                                 
kW-mo/yr
 | - | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $493 | $502 | $409 6,741
                                 
kWh
 | $84 -
                                 
kW-mo/yr
 | - | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,395 | $1,350 | $6,395 82,943
                                 
kWh
 | - | - | - | - | |
| 04 | 3.2176: Increase use of automation | $32,049 | - | - | - | - | $32,049 | - | |
| 05 | 3.5316: Contract a wood pallet recycling company | $9,000 | - | - | - | $9,000 -
                                 
lb
 | - | - | |
| 06 | 3.6192: Use a less expensive method of waste removal | $554 | - | - | - | - | - | $554 | |
| TOTAL RECOMMENDED | $55,254 | $25,761 | $12,425 180,247
                                 
kWh
 | $1,226 -
                                 
kW-mo/yr
 | $9,000 -
                                 
lb
 | $32,049 | $554 | ||
| TOTAL IMPLEMENTED | $16,442 | $1,852 | $6,804 89,684
                                 
kWh
 | $84 -
                                 
kW-mo/yr
 | $9,000 -
                                 
lb
 | - | $554 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs
             
             
             
            