| Assessment Year | 1997 |
|---|---|
| Principal Product | Custom printed products |
| NAICS |
n/a
|
| SIC | 2761: Manifold Business Forms |
| Sales Range | $50 M to 100M |
| # of Employees | 48 |
| Plant Area |
47,000
ft2
|
| Annual Production | 470,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $98,349 | 1,180,246 |
kWh
|
$0.083 |
| Electricity Demand | $24,841 | 2,946 |
kW-mo/yr
|
$8.43 |
| LPG | $2,215 | 112 |
MMBtu
|
$19.78 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,655 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,858 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | By-product Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,171 | $7,641 |
$2,421
53,634
kWh
|
$750
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 02 | 2.7145: Install skylights | $682 | $480 |
$682
15,240
kWh
|
- | - | - | - | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $840 | $2,986 |
$587
13,189
kWh
|
$253
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,043 | $750 |
$1,043
15,826
kWh
|
- | - | - | - | - | - | - | |
| 05 | 4.511: Expand operations into unused space | $3,377 | - | - | - | - | - | $(-5,265.0) | $(-4,358.0) | - | $13,000 | |
| 06 | 3.8133: Convert to aqueous cleaning | $3,420 | - | - | - | - |
$1,950
-
gal
|
- | - | $1,470 | - | |
| 07 | 3.3131: Use evaporation to concentrate material | $10,122 | $4,450 | - | - |
$10,122
-
gal
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $22,655 | $16,307 |
$4,733
97,889
kWh
|
$1,003
-
kW-mo/yr
|
$10,122
-
gal
|
$1,950
-
gal
|
$(-5,265.0) | $(-4,358.0) | $1,470 | $13,000 | ||
| TOTAL IMPLEMENTED | $15,858 | $16,307 |
$4,733
97,889
kWh
|
$1,003
-
kW-mo/yr
|
$10,122
-
gal
|
- | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | By-product Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs