Assessment Year | 1996 |
---|---|
Principal Product | Frozen Food |
NAICS |
n/a
|
SIC | 2038: Frozen Specialties, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 490 |
Plant Area |
180,000
ft2
|
Annual Production | 95,000,000
lb
|
Production Hrs. Annual | 4,030
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $693,409 | 24,513,189 |
kWh
|
$0.028 |
Electricity Demand | $398,353 | 29,464 |
kW-mo/yr
|
$13.52 |
Natural Gas | $211,081 | 55,951 |
MMBtu
|
$3.77 |
LPG | $27,279 | 2,256 |
MMBtu
|
$12.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $53,873 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,710 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,572 | $32,094 |
$8,734
436,694
kWh
|
$7,838
-
kW-mo/yr
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $2,091 | $2,802 |
$950
47,479
kWh
|
$1,141
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,841 | $1,350 |
$4,841
242,087
kWh
|
- | - | |
04 | 2.2615: Clean condenser tubes | $19,869 | - |
$19,869
1,569,461
kWh
|
- | - | |
05 | 3.1291: Eliminate practice of mixing waste streams | $10,500 | $400 | - | - |
$10,500
-
Tgal
|
|
TOTAL RECOMMENDED | $53,873 | $36,646 |
$34,394
2,295,721
kWh
|
$8,979
-
kW-mo/yr
|
$10,500
-
Tgal
|
||
TOTAL IMPLEMENTED | $24,710 | $1,350 |
$24,710
1,811,548
kWh
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs