| Assessment Year | 1996 |
|---|---|
| Principal Product | Bottling Soda Products |
| NAICS |
n/a
|
| SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
150,000
ft2
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 5,330
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $100,971 | 1,804,220 |
kWh
|
$0.056 |
| Electricity Demand | $30,636 | 7,331 |
kW-mo/yr
|
$4.18 |
| Natural Gas | $27,556 | 6,492 |
MMBtu
|
$4.24 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $27,847 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,998 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,316 | $7,288 |
$3,693
65,944
kWh
|
$623
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $491 | $6,951 |
$476
8,499
kWh
|
$15
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $546 | $500 |
$377
6,741
kWh
|
$169
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,132 | $1,000 |
$2,132
29,308
kWh
|
- | - | - | - | |
| 05 | 2.2441: Preheat boiler makeup water with waste process heat | $8,171 | $7,500 | - | - |
$8,171
-
MMBtu
|
- | - | |
| 06 | 3.4113: Treat and reuse rinse waters | $816 | $865 | - | - | - |
$816
-
Tgal
|
- | |
| 07 | 4.321: Optimize production lot sizes and inventories | $11,375 | $7,000 | - | - | - | - |
$11,375
-
gal
|
|
| TOTAL RECOMMENDED | $27,847 | $31,104 |
$6,678
110,492
kWh
|
$807
-
kW-mo/yr
|
$8,171
-
MMBtu
|
$816
-
Tgal
|
$11,375
-
gal
|
||
| TOTAL IMPLEMENTED | $13,998 | $14,951 |
$2,608
37,807
kWh
|
$15
-
kW-mo/yr
|
- | - |
$11,375
-
gal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs