Assessment Year | 2022 |
---|---|
Principal Product | Polymer Materials |
NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 600 |
Plant Area |
222,000
ft2
|
Annual Production | 200
units
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,198,549 | 16,922,046 |
kWh
|
$0.071 | |
Electricity Demand | $213,241 | 30,461 |
kW-mo/yr
|
$7.00 | |
Electricity Fees | $4,246 | - |
|
- | |
Natural Gas | $672,420 | 95,439 |
MMBtu
|
$7.05 | |
Waste Disposal Costs | |||||
Water Usage | $177,451 | 9,546 |
Tgal
|
$18.59 | |
TOTAL YEARLY COSTS | $2,265,907 | ||||
RECOMMENDED SAVINGS* | $547,046 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $19,290 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $41,792 | - | - | - |
$41,792
-
MMBtu
|
- | |
02 | 2.6232: Install set-back timers | $14,339 | $1,650 |
$5,379
75,759
kWh
|
$909
-
kW-mo/yr
|
$8,051
-
MMBtu
|
- | |
03 | 2.6232: Install set-back timers | $4,951 | $2,500 |
$2,137
30,100
kWh
|
$361
-
kW-mo/yr
|
$2,453
-
MMBtu
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $264,494 | - |
$226,254
3,186,671
kWh
|
$38,240
-
kW-mo/yr
|
- | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $93,984 | $5,553 |
$49,175
692,608
kWh
|
$8,311
-
kW-mo/yr
|
$36,498
-
MMBtu
|
- | |
06 | 3.4154: Eliminate leaks in water lines and valves | $17,648 | $50,000 | - | - |
$5,894
-
MMBtu
|
$11,754
-
Tgal
|
|
07 | 2.1241: Reduce excessive boiler blowdown | $17,995 | - | - | - |
$9,179
-
MMBtu
|
$8,816
-
Tgal
|
|
08 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $5,443 | $20,000 | - | - |
$5,443
-
MMBtu
|
- | |
09 | 2.2622: Replace existing chiller with high efficiency model | $86,400 | $1,000,000 |
$73,911
1,041,000
kWh
|
$12,489
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $547,046 | $1,079,703 |
$356,856
5,026,138
kWh
|
$60,310
-
kW-mo/yr
|
$109,310
-
MMBtu
|
$20,570
-
Tgal
|
||
TOTAL IMPLEMENTED | $19,290 | $4,150 |
$7,516
105,859
kWh
|
$1,270
-
kW-mo/yr
|
$10,504
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs