Assessment Year | 1996 |
---|---|
Principal Product | Filter Assemblies |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 170 |
Plant Area |
140,000
ft2
|
Annual Production | 55,000
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $228,598 | 4,345,252 |
kWh
|
$0.053 |
Electricity Demand | $46,833 | 10,127 |
kW-mo/yr
|
$4.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,711 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,832 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,550 | $25,740 |
$9,770
184,349
kWh
|
$1,780
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,689 | $6,564 |
$5,689
107,268
kWh
|
- | - | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $27,649 | $23,150 |
$21,767
410,610
kWh
|
$5,882
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,183 | $800 |
$1,183
18,757
kWh
|
- | - | |
05 | 3.4116: Meter recycled water (to reduce sewer charges) | $2,640 | $4,550 | - | - |
$2,640
-
Tgal
|
|
TOTAL RECOMMENDED | $48,711 | $60,804 |
$38,409
720,984
kWh
|
$7,662
-
kW-mo/yr
|
$2,640
-
Tgal
|
||
TOTAL IMPLEMENTED | $28,832 | $23,950 |
$22,950
429,367
kWh
|
$5,882
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs