Assessment Year | 1996 |
---|---|
Principal Product | Sodium hypochlorite |
NAICS |
n/a
|
SIC | 2842: Specialty Cleaning, Polishing, and Sanitation Preparations |
Sales Range | $10 M to 50M |
# of Employees | 32 |
Plant Area |
208,900
ft2
|
Annual Production | 27,000
Tgal
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $96,684 | 1,476,260 |
kWh
|
$0.065 |
Electricity Demand | $19,067 | 4,312 |
kW-mo/yr
|
$4.42 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,628 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,137 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,863 | $4,964 |
$1,565
24,033
kWh
|
$298
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,022 | $1,341 |
$868
13,189
kWh
|
$154
-
kW-mo/yr
|
|
03 | 2.4133: Use most efficient type of electric motors | $1,606 | $2,649 |
$1,344
20,516
kWh
|
$262
-
kW-mo/yr
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,137 | $700 |
$4,137
57,444
kWh
|
- | |
TOTAL RECOMMENDED | $8,628 | $9,654 |
$7,914
115,182
kWh
|
$714
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $4,137 | $700 |
$4,137
57,444
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs