| Assessment Year | 1996 |
|---|---|
| Principal Product | Concrete Pipe |
| NAICS |
n/a
|
| SIC | 3272: Concrete Products, Except Block and Brick |
| Sales Range | $10 M to 50M |
| # of Employees | 118 |
| Plant Area |
150,000
ft2
|
| Annual Production | 175,000
ton
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $81,076 | 1,601,407 |
kWh
|
$0.051 |
| Electricity Demand | $48,301 | 5,552 |
kW-mo/yr
|
$8.70 |
| Natural Gas | $22,920 | 5,069 |
MMBtu
|
$4.52 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $42,826 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,147 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | By-product Production Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,631 | $828 |
$1,910
37,515
kWh
|
$721
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7134: Use photocell controls | $499 | $660 |
$499
9,672
kWh
|
- | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $1,145 | $2,649 |
$728
14,361
kWh
|
$417
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $371 | $500 |
$371
7,327
kWh
|
- | - | - | - | |
| 05 | 3.1182: Make a new by-product | $5,880 | - | - | - | - | - | $5,880 | |
| 06 | 3.2176: Increase use of automation | $9,800 | $21,000 | - | - | - | $9,800 | - | |
| 07 | 3.1192: Reduce scrap production | $22,500 | $18,000 | - | - | $22,500 | - | - | |
| TOTAL RECOMMENDED | $42,826 | $43,637 |
$3,508
68,875
kWh
|
$1,138
-
kW-mo/yr
|
$22,500 | $9,800 | $5,880 | ||
| TOTAL IMPLEMENTED | $4,147 | $3,977 |
$3,009
59,203
kWh
|
$1,138
-
kW-mo/yr
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | By-product Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs