| Assessment Year | 1996 |
|---|---|
| Principal Product | Animal Feed |
| NAICS |
n/a
|
| SIC | 2048: Prepared Feed and Feed Ingredients for Animals and Fowls, Except Dogs and Cats |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
100,000
ft2
|
| Annual Production | 30,000
ton
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $63,707 | 1,247,362 |
kWh
|
$0.051 |
| Electricity Demand | $52,963 | 5,180 |
kW-mo/yr
|
$10.22 |
| Natural Gas | $8,927 | 1,710 |
MMBtu
|
$5.22 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $95,558 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,549 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,468 | $2,440 |
$1,012
19,930
kWh
|
$456
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $81 | $444 |
$81
4,396
kWh
|
- | - | - | - | - | - | |
| 03 | 2.3212: Optimize plant power factor | $16,942 | $15,758 | - | - | $16,942 | - | - | - | - | |
| 04 | 2.4131: Size electric motors for peak operating efficiency | $707 | $(-7,300.0) |
$507
9,965
kWh
|
$200
-
kW-mo/yr
|
- | - | - | - | - | |
| 05 | 3.1191: Change procedures / equipment / operating conditions | $76,086 | $125,114 |
$(-2,473.0)
(-26,377)
kWh
|
- | - | $32,880 | - | $3,679 | $42,000 | |
| 06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $274 | - | - | - | - | - | $274 | - | - | |
| TOTAL RECOMMENDED | $95,558 | $136,456 |
$(-873.0)
7,914
kWh
|
$656
-
kW-mo/yr
|
$16,942 | $32,880 | $274 | $3,679 | $42,000 | ||
| TOTAL IMPLEMENTED | $1,549 | $2,884 |
$1,093
24,326
kWh
|
$456
-
kW-mo/yr
|
- | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs