Assessment Year 1996
Principal Product Plastic Valves
NAICS
n/a
SIC 3841: Surgical and Medical Instruments and Apparatus
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 72,000
ft2
Annual Production 300,000,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $204,351 3,802,169
kWh
Electricity Demand $35,708 7,724
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $36,311 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $23,743

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $10,578 $22,632 $8,665
160,610
kWh
$1,913
-
kW-mo/yr
-
02 2.4133: Use most efficient type of electric motors $2,249 $2,934 $1,999
37,222
kWh
$250
-
kW-mo/yr
-
03 2.7232: Replace existing hvac unit with high efficiency model $18,184 $13,550 $15,652
289,859
kWh
$2,532
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,365 $750 $2,365
37,515
kWh
- -
05 2.4314: Use synthetic lubricant $945 $250 $945
8,792
kWh
- -
06 3.1162: Use less wasteful packaging $1,990 $4,000 - - $1,990
TOTAL RECOMMENDED $36,311 $44,116 $29,626
533,998
kWh
$4,695
-
kW-mo/yr
$1,990
TOTAL IMPLEMENTED $23,743 $17,484 $20,961
373,388
kWh
$2,782
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs