Assessment Year | 1995 |
---|---|
Principal Product | Printed Circuit Board Assemblies |
NAICS |
n/a
|
SIC | 3672: Printed Circuit Boards |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
56,000
ft2
|
Annual Production | 1,500,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $244,042 | 3,952,227 |
kWh
|
$0.062 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $63,698 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $33,460 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $29,637 | $32,604 |
$29,637
517,585
kWh
|
|
02 | 2.7135: Install occupancy sensors | $4,087 | $192 |
$4,087
77,081
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $2,055 | $1,094 |
$2,055
34,877
kWh
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,399 | $40,610 |
$14,399
248,242
kWh
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,768 | $350 |
$1,768
28,429
kWh
|
|
06 | 2.2622: Replace existing chiller with high efficiency model | $7,950 | $15,000 |
$7,950
150,059
kWh
|
|
07 | 2.3137: Use power during off-peak periods | $3,802 | - |
$3,802
-
kWh
|
|
TOTAL RECOMMENDED | $63,698 | $89,850 |
$63,698
1,056,273
kWh
|
||
TOTAL IMPLEMENTED | $33,460 | $34,048 |
$33,460
580,891
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs