Assessment Year | 1995 |
---|---|
Principal Product | Sun care products |
NAICS |
n/a
|
SIC | 2844: Perfumes, Cosmetics, and Other Toilet Preparations |
Sales Range | $50 M to 100M |
# of Employees | 275 |
Plant Area |
190,000
ft2
|
Annual Production | 25,000,000
pieces
|
Production Hrs. Annual | 5,600
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $271,997 | 4,107,269 |
kWh
|
$0.066 |
LPG | $22,973 | 2,959 |
MMBtu
|
$7.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $91,346 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,229 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $836 | $646 |
$836
11,723
kWh
|
- | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $8,168 | $750 |
$8,168
106,389
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $2,643 | $768 |
$2,643
61,547
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,130 | $350 |
$4,130
62,720
kWh
|
- | - | |
05 | 2.4133: Use most efficient type of electric motors | $2,931 | $4,920 |
$2,931
41,911
kWh
|
- | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,330 | $12,000 |
$3,330
57,444
kWh
|
- | - | |
07 | 2.8114: Change rate schedules or other changes in utility service | $59,898 | $100,000 | - | - | $59,898 | |
08 | 4.321: Optimize production lot sizes and inventories | $5,730 | $7,000 | - | - | $5,730 | |
09 | 3.8137: Use soy or water-based inks | $3,680 | - | - |
$3,680
-
gal
|
- | |
TOTAL RECOMMENDED | $91,346 | $126,434 |
$22,038
341,734
kWh
|
$3,680
-
gal
|
$65,628 | ||
TOTAL IMPLEMENTED | $15,229 | $6,020 |
$15,229
211,020
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs