Assessment Year | 1995 |
---|---|
Principal Product | Aluminum Fuel Tanks |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $5 M to 10M |
# of Employees | 65 |
Plant Area |
94,000
ft2
|
Annual Production | 30,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $31,743 | 595,545 |
kWh
|
$0.053 |
Natural Gas | $799 | 107 |
MMBtu
|
$7.47 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,108 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,717 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $1,065 | - |
$1,065
20,223
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $457 | $935 |
$457
9,086
kWh
|
|
03 | 2.7232: Replace existing hvac unit with high efficiency model | $411 | $500 |
$411
7,620
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $784 | $200 |
$784
14,654
kWh
|
|
05 | 2.4133: Use most efficient type of electric motors | $858 | $2,485 |
$858
15,826
kWh
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $78 | $300 |
$78
1,758
kWh
|
|
07 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $455 | $1,450 |
$455
10,258
kWh
|
|
TOTAL RECOMMENDED | $4,108 | $5,870 |
$4,108
79,425
kWh
|
||
TOTAL IMPLEMENTED | $2,717 | $1,635 |
$2,717
51,583
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |