| Assessment Year | 1995 |
|---|---|
| Principal Product | Aluminum Fuel Tanks |
| NAICS |
n/a
|
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $5 M to 10M |
| # of Employees | 65 |
| Plant Area |
94,000
ft2
|
| Annual Production | 30,000
pieces
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $31,743 | 595,545 |
kWh
|
$0.053 |
| Natural Gas | $799 | 107 |
MMBtu
|
$7.47 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,108 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,717 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $1,065 | - |
$1,065
20,223
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $457 | $935 |
$457
9,086
kWh
|
|
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $411 | $500 |
$411
7,620
kWh
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $784 | $200 |
$784
14,654
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $858 | $2,485 |
$858
15,826
kWh
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $78 | $300 |
$78
1,758
kWh
|
|
| 07 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $455 | $1,450 |
$455
10,258
kWh
|
|
| TOTAL RECOMMENDED | $4,108 | $5,870 |
$4,108
79,425
kWh
|
||
| TOTAL IMPLEMENTED | $2,717 | $1,635 |
$2,717
51,583
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs