Assessment Year 1995
Principal Product Skylights
NAICS
n/a
SIC 3444: Sheet Metal Work
Sales Range $5
M
to 10
M
# of Employees 40
Plant Area 64,000
ft2
Annual Production 40,000
pieces
Production Hrs. Annual 2,100
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $73,502 935,229
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $17,154 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $611

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7111: Reduce illumination to minimum necessary levels $1,471 - $1,471
18,757
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $190 $71 $190
2,638
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $152 $360 $152
2,052
kWh
04 2.5194: Redesign process $14,920 $19,775 $14,920
184,056
kWh
05 2.4133: Use most efficient type of electric motors $307 $966 $307
3,810
kWh
06 2.1131: Repair faulty insulation in furnaces, boilers, etc $114 $250 $114
2,052
kWh
TOTAL RECOMMENDED $17,154 $21,422 $17,154
213,365
kWh
TOTAL IMPLEMENTED $611 $1,287 $611
8,500
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings