| Assessment Year | 1995 |
|---|---|
| Principal Product | Skylights |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
64,000
ft2
|
| Annual Production | 40,000
pieces
|
| Production Hrs. Annual | 2,100
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $73,502 | 935,229 |
kWh
|
$0.079 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,154 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $611 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $1,471 | - |
$1,471
18,757
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $190 | $71 |
$190
2,638
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $152 | $360 |
$152
2,052
kWh
|
|
| 04 | 2.5194: Redesign process | $14,920 | $19,775 |
$14,920
184,056
kWh
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $307 | $966 |
$307
3,810
kWh
|
|
| 06 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $114 | $250 |
$114
2,052
kWh
|
|
| TOTAL RECOMMENDED | $17,154 | $21,422 |
$17,154
213,365
kWh
|
||
| TOTAL IMPLEMENTED | $611 | $1,287 |
$611
8,500
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs