Assessment Year | 1995 |
---|---|
Principal Product | Granular Fertilizer |
NAICS |
n/a
|
SIC | 2875: Fertilizers, Mixing Only |
Sales Range | $10 M to 50M |
# of Employees | 25 |
Plant Area |
6,500,000
ft2
|
Annual Production | 180,000,000
lb
|
Production Hrs. Annual | 4,784
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $140,704 | 1,708,089 |
kWh
|
$0.082 |
Natural Gas | $70,276 | 18,033 |
MMBtu
|
$3.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,989 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,038 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,779 | $5,399 |
$11,779
164,127
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,775 | $5,159 |
$1,775
24,912
kWh
|
- | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $2,452 | $400 |
$2,452
11,137
kWh
|
- | |
04 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $724 | $2,600 | - |
$724
-
MMBtu
|
|
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $870 | $1,000 | - |
$870
-
MMBtu
|
|
06 | 2.4133: Use most efficient type of electric motors | $1,796 | $5,186 |
$1,796
23,740
kWh
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $593 | $500 |
$593
7,327
kWh
|
- | |
TOTAL RECOMMENDED | $19,989 | $20,244 |
$18,395
231,243
kWh
|
$1,594
-
MMBtu
|
||
TOTAL IMPLEMENTED | $15,038 | $12,085 |
$14,168
195,194
kWh
|
$870
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs