Assessment Year | 1995 |
---|---|
Principal Product | Circuit Boards |
NAICS |
n/a
|
SIC | 3679: Electronic Components, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 250 |
Plant Area |
256,000
ft2
|
Annual Production | 250
pieces
|
Production Hrs. Annual | 2,300
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $517,456 | 8,357,562 |
kWh
|
$0.062 |
Natural Gas | $6,304 | 3,089 |
MMBtu
|
$2.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $76,522 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,705 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,375 | $3,338 |
$2,375
35,170
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $29,924 | $84,732 |
$29,924
415,592
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $1,579 | $1,457 |
$1,579
26,377
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,827 | $350 |
$18,827
289,566
kWh
|
|
05 | 2.7492: Use proper thickness of insulation on building envelope | $20,739 | $18,879 |
$20,739
313,599
kWh
|
|
06 | 2.7135: Install occupancy sensors | $3,078 | $2,752 |
$3,078
44,549
kWh
|
|
TOTAL RECOMMENDED | $76,522 | $111,508 |
$76,522
1,124,853
kWh
|
||
TOTAL IMPLEMENTED | $52,705 | $89,877 |
$52,705
766,705
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs