| Assessment Year | 1995 |
|---|---|
| Principal Product | Fiberglass Boats |
| NAICS |
n/a
|
| SIC | 3732: Boat Building and Repairing |
| Sales Range | $50 M to 100M |
| # of Employees | 500 |
| Plant Area |
340,000
ft2
|
| Annual Production | 2,300
pieces
|
| Production Hrs. Annual | 4,368
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $260,532 | 4,195,193 |
kWh
|
$0.062 |
| LPG | $19,337 | 1,550 |
MMBtu
|
$12.48 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $91,223 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $33,401 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $31,040 | $7,890 |
$31,040
419,988
kWh
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,741 | $23,485 |
$7,741
128,664
kWh
|
- | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $5,754 | $10,491 |
$5,754
89,683
kWh
|
- | - | - | |
| 04 | 2.7232: Replace existing hvac unit with high efficiency model | $7,198 | $4,450 |
$7,198
106,682
kWh
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,793 | $10,316 |
$2,793
42,204
kWh
|
- | - | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $604 | $975 |
$604
11,430
kWh
|
- | - | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,350 | $5,610 |
$10,350
152,110
kWh
|
- | - | - | |
| 08 | 3.8132: Use less toxic and volatile solvent substitutes | $8,112 | - | - |
$(-46,608.0)
-
gal
|
$54,720
-
gal
|
- | |
| 09 | 4.321: Optimize production lot sizes and inventories | $17,631 | $7,000 | - | - | - | $17,631 | |
| TOTAL RECOMMENDED | $91,223 | $70,217 |
$65,480
950,761
kWh
|
$(-46,608.0)
-
gal
|
$54,720
-
gal
|
$17,631 | ||
| TOTAL IMPLEMENTED | $33,401 | $33,545 |
$25,289
387,456
kWh
|
$(-46,608.0)
-
gal
|
$54,720
-
gal
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs