Assessment Year | 1995 |
---|---|
Principal Product | Grenade Fuses |
NAICS |
n/a
|
SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
8,000,000
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 3,960
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $257,541 | 3,152,403 |
kWh
|
$0.082 |
Fuel Oil #2 | $3,180 | 541 |
MMBtu
|
$5.88 |
Other Gas | $73,253 | 10,596 |
MMBtu
|
$6.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,555 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,859 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,538 | $13,360 |
$5,538
62,427
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,068 | $2,078 |
$1,068
12,603
kWh
|
|
03 | 2.7135: Install occupancy sensors | $341 | $256 |
$341
5,569
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $226 | $320 |
$226
2,638
kWh
|
|
05 | 2.4133: Use most efficient type of electric motors | $819 | $1,911 |
$819
9,965
kWh
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $434 | $500 |
$434
7,327
kWh
|
|
07 | 2.6242: Minimize operation of equipment maintained in standby condition | $10,129 | $1,500 |
$10,129
168,816
kWh
|
|
TOTAL RECOMMENDED | $18,555 | $19,925 |
$18,555
269,345
kWh
|
||
TOTAL IMPLEMENTED | $7,859 | $17,849 |
$7,859
92,322
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs